Page 1 - T30.30306.02

7(&+1,&$/,16758&7,216)&;T30.30306.02

Page 2 - 7$%/(2)&217(176

,167$//$7,217\SLFDOLQVWDOODWLRQH[DPSOHVThe flue/combustion air system piping may be eitherhorizontal or vertical or a combination of both, o

Page 3 - ,,1752'8&7,21

,167$//$7,217\SLFDOLQVWDOODWLRQH[DPSOHVFRQWOptions: - 1 90 deg concentric elbow- Concentric extensions- 1 concentric vertical terminal- 1

Page 4 - Rear view

,167$//$7,217\SLFDOLQVWDOODWLRQH[DPSOHVFRQWOptions: - 1 45 deg concentric elbow- 1 90 deg concentric elbow- Concentric extensions- 1 conce

Page 5 -   %2,/(523(5$7,21

,167$//$7,217\SLFDOLQVWDOODWLRQH[DPSOHVFRQWOptions: - 1 45 deg concentric elbow- 2 90 deg concentric elbow- 1 concentric extension- 1 stra

Page 6

,167$//$7,21  :$7(5&,5&8,7&211(&7,216Water circuit connections are made in the back ofthe unit utilizing the four 1" ma

Page 7 - ,,,167$//$7,21

,167$//$7,21Various typical water circuits (cont)&RQQHFWLRQWRDGRXEOHKHDWLQJFLUFXLW&RQQHFWLRQWRDGRXEOHKHDWLQJFLUFXLWZLWKDGRP

Page 8 - 5HIHUHQFH

,167$//$7,21  (/(&75,&$/&211(&7,216:$51,1*(/(&75,&$/6+2&.+$=$5'',6&211(&77+(32:(56833/

Page 9

,167$//$7,21The hole in the right rear of the unit is a large flatoval. Mount a Listed 2 x 4 inch, "HandiBox" typejunction box over th

Page 10

,,,67$5783$1'23(5$7,21  35(67$57),1$/6<67(0&+(&.Before starting normal operation of the boiler andheating system, pe

Page 11

67$5783$1'23(5$7,21  $'-867,1*7+(2,/%851(5While the oil burner is adjusted at the factory, it is re-commended that the operati

Page 12 - ≤IWP

7$%/(2)&217(176,  ,1752'8&7,21 

Page 13 - 90° elbow

,90$,17(1$1&(It is recommend that the boiler and flue/combustionair system be inspected and maintained annually bya qualified technician.

Page 14

0$,17(1$1&(  %851(50$,17(1$1&(Once adjusted properly, regular maintenance of theoil burner is not generally required. A routine exami

Page 15

0$,17(1$1&(  &+$1*,1*$7+(50267$7257+(7+(5020(7(5Replacement of the thermostats or the thermometerrequires removal of the bulb fro

Page 16 - ,167$//$7,212)7+(81,7

923(5$7,1*)$8/76During the course of seemingly normal operation,there may be operating faults experienced in thesystem. Some of the more com

Page 17 -  2YDO+ROH

MPI - P.O. BOX 3408 PRINCETON, NEW JERSEY 08543 - PHONE 800/524-1102 (NJ 732/329-0900) FAX 732/329-0904SEPTEMBRE 2001

Page 18

,,1752'8&7,21  352'8&7'(6&5,37,21Model FCX oil fired boiler utilizes a sealed combus-tion system that operates a

Page 19

,1752'8&7,21'(6,*1$7,212)&20321(1762310145678911121314158171819202122231141718192021222324162526 &RQWURO3DQHO &

Page 20 - ,90$,17(1$1&(

,1752'8&7,21  %2,/(523(5$7,21Combustion air is drawn into the oil burner by theburner fan through the air intake hose connected tothe

Page 21 -   %851(50$,17(1$1&(

,1752'8&7,21  352'8&767$1'$5'5$7,1*6Ratings for Model FCX are provided in the followingtable:Ratings are for the

Page 22

,,,167$//$7,21  23(1,1*7+(81,7To open Model FCX to access for installation, and/or service, follow these steps :- Remove the control panel

Page 23 - 923(5$7,1*)$8/76

,167$//$7,21  )/8(&211(&7,216$1'5287,1*Connection of the coaxial flue/combustion air pipingsystem is in the back of the unit to

Page 24 - SEPTEMBRE 2001

,167$//$7,216OHHYH7LOHZLWK$GDSWDEOH&RXSOLQJ3RO\SURS\OHQH39&&RQFHQWULF(OERZ- joint fitting - )DVWHQLQJFROODURSWLRQCollars a